Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 162
Filter
1.
Braz. oral res. (Online) ; 38: e001, 2024. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1528143

ABSTRACT

Abstract The aim of this study was to evaluate the influence of adding quaternary ammonium methacrylates (QAMs) to experimental adhesives by assessing the degree of conversion (DC), cytotoxicity against keratinocytes and fibroblasts, and antibacterial activity against biofilm formation. Two QAMs were added to an experimental adhesive: dimethylaminododecyl methacrylate bromododecane (DMADDM) or dimethylaminododecyl methacrylate bromohexadecane (DMAHDM) at three concentrations each: 1, 2.5, and 5 wt.%. Experimental adhesive without QAMs (control group) and commercially available Transbond XT Primer (3M Unitek, Monrovia, California, USA) were used for comparisons. The adhesives were tested for DC, cytotoxicity against keratinocytes and fibroblasts, and antibacterial activity against biofilm formation. DC, cytotoxicity against fibroblasts, and antibacterial activity were analyzed using one-way ANOVA and Tukey's multiple comparisons. Cytotoxicity against keratinocytes was evaluated using the Kruskal Wallis and Dunn's post-hoc (α = 5%) tests. Transbond showed lower DC as compared to 5% DMAHDM, 1% DMADDM, and 5% DMADDM (p < 0.05). However, all groups presented proper DC when compared to commercial adhesives in the literature. In the evaluation of cytotoxicity against keratinocytes, Transbond induced higher viability than 2.5 wt.% groups (p < 0.05). Against fibroblasts, Transbond induced higher viability as compared to 5 wt.% groups (p < 0.05). DMAHDM at 5 wt.% reduced biofilm formation when compared to all the other groups (p < 0.05). Despite their cytotoxic effect against keratinocytes, gingival fibroblasts showed higher viability. DMAHDM at 5 wt.% decreased Streptococcus mutans viability. The incorporation of DMAHDM at 5 wt.% may be a strategy for reducing the development of white spot lesions.

2.
Odovtos (En linea) ; 25(1)abr. 2023.
Article in English | LILACS, SaludCR | ID: biblio-1422190

ABSTRACT

Dental fluorosis can cause changes in the enamel surface, conditioning its functionality and esthetics. The application of dental adhesives is a treatment option; however, their use on fluorotic teeth can result in limitations. The aim of this study was to compare the shear bond strength of two different adhesives, one with 10-MDP and one without 10-MDP, in different degrees of dental fluorosis.This is an in vitro study on dental enamel samples, a total of 180 samples with the inclusion criteria were treated, randomly divided into two groups of 90, according to the type of dental adhesive, where each group was again divided into three groups of 30 samples, representing different degrees of dental fluorosis according to the Thylstrup-Fejerskov index (Group I: TF1 and TF2; Group II: TF3; Group III: TF4). Normality tests, two-factor ANOVA, and post-hoc tests were used to determine differences between the groups, with a significance level of 95%. As results, a statistically significant difference was shown between the use of dental adhesive with 10-MDP and the three groups of dental fluorosis (p=0.011), in addition, a Tukey post-hoc test on the groups treated with 10-MDP adhesive revealed a statistically significant difference between group I versus group II, and group I versus group III, (p=<0.05). It is concluded that the use of adhesive systems with 10-MDP presents a better shear bond strength on enamel with dental fluorosis grades I and II in the Thylstrup-Fejerskov index.


La fluorosis dental puede ocasionar cambios en la superficie del esmalte, condicionando su funcionalidad y estética, la aplicación de adhesivos dentales es una opción de tratamiento, sin embargo, su uso en dientes fluoroticos puede resultar en limitaciones. El objetivo de este estudio consistió en comparar la fuerza de adhesión a la cizalladura de dos diferentes adhesivos, uno con 10-MDP y otro sin 10-MDP, en diferentes grados de fluorosis dental. Se trata de un estudio in vitro en muestras de esmalte dental, un total de 180 muestras con los criterios de inclusión fueron tratadas, aleatoriamente divididas en dos grupos de 90, de acuerdo al tipo de adhesivo dental, donde cada grupo fue dividido nuevamente en tres grupos de 30 muestras, representando diferentes grados de fluorosis dental según el índice de Thylstrup- Fejerskov (Grupo I: TF1 y TF2; Grupo II: TF3; Grupo III: TF4). Para determinar diferencias entre los grupos se utilizaron pruebas de normalidad, ANOVA de dos factores, y pruebas post-hoc, con un nivel de significancia de 95%. Como resultados, se mostró una diferencia estadísticamente significativa entre el uso de adhesivo dental con 10- MDP y los tres grupos de fluorosis dental (p=0.011), además, una prueba post hoc de Tukey sobre los grupos tratados con adhesivo 10-MDP revelaron una diferencia estadísticamente significativa entre el grupo I frente al grupo II, y el grupo I frente al grupo III, (p=<0.05) Se concluye que el uso de sistemas adhesivos con 10-MDP presentan una mejor resistencia de adhesión al cizallamiento en esmalte con grados de fluorosis dental I y II en el índice de Thylstrup-Fejerskov


Subject(s)
Dentin-Bonding Agents/therapeutic use , Fluorosis, Dental/diagnosis , Resin Cements
3.
J. oral res. (Impresa) ; 12(1): 204-216, abr. 4, 2023. tab, ilus
Article in English | LILACS | ID: biblio-1518183

ABSTRACT

Aim: To evaluate the bond strength of a universal adhesive system to dentin submitted to radiotherapy. Materials and Methods: Sixty extracted human teeth were divided into two groups (n = 30): without radiotherapy (control); with radiotherapy, according to the adhesive protocol (n=15): ER-etch-and-rinse (acid + Single Bond Uni-versal); SE-self-etch (Single Bond Universal). The analyzes were shear bond strength (SBS) (n=10), failure pattern (n=10) and scanning electron microscopy (n=5). Data was analyzed by a two-way ANOVA (α =0.05). Results: The radiotherapy decreased SBS of the restorative material to dentin (p<0.0001). The ER protocol provided lower bond strength values (p<0.001). The predominant type of fracture without radiotherapy was mixed (SE), cohesive to the material (ER). Both protocols presented adhesive failures with radiotherapy. Teeth had a hybrid layer and long resin tags (without radiotherapy) and few tags (with radiotherapy). Conclusions: The SE adhesive mode favors the shear bond strength of resin to dentin in teeth submitted to radiotherapy.


Objetivo: Evaluar la fuerza de adhesión de un sistema adhesivo universal a la dentina sometida a radioterapia. Materiales y Métodos: Sesenta dientes humanos extraídos se dividieron en dos grupos (n = 30): sin radioterapia (control); con radioterapia, según protocolo adhesivo (n=15): ER-grabado y enjuague (ácido + Single Bond Universal); autograbado SE (Single Bond Universal). Los análisis ejecutados fueron resistencia al cizallamiento (SBS) (n=10), patrón de falla (n=10) y microscopía electrónica de barrido (n=5). Los datos se sometieron al test de ANOVA de dos vías (α =0,05). Resultados: La radioterapia disminuyó la SBS del material restaurador a la dentina (p<0,0001). El protocolo ER proporcionó valores de fuerza de unión más bajos (p<0,001). El tipo de fractura predominante sin radioterapia fue mixta (SE), cohesiva al material (ER). Ambos protocolos presentaron fallas adhesivas con radioterapia. Los dientes tenían una capa híbrida y colas de resina largas (sin radioterapia) o pocas colas de resina (con radioterapia). Conclusión: El modo adhesivo SE favorece la resistencia al corte de la resina a la dentina en dientes sometidos a radioterapia.


Subject(s)
Humans , Dental Bonding/methods , Dentin-Bonding Agents/chemistry , Dental Cements/chemistry , Dental Stress Analysis/methods , Composite Resins , Dentin
4.
Braz. j. oral sci ; 22: e237617, Jan.-Dec. 2023. ilus
Article in English | LILACS, BBO | ID: biblio-1435226

ABSTRACT

Aim: To evaluate the bottom/top hardness ratio (B/T) and the dentin bonding stability of conventional and bulk-fill resin composites in high c-factor preparations. Methods: Regular conventional (Tetric N-Ceram ­ TNC, and Polofil Supra ­ PFS), regular bulk-fill (Tetric N-Ceram Bulk fill ­ TBF, and Admira Fusion X-tra ­ AFX), and low viscosity bulk-fill resin composites (Tetric N-flow ­ TNF, and X-tra Base ­ XTB) were used to restore 180 dentin conical preparations. The specimens were randomly distributed in 12 groups (n = 15) according to the resin composites and storage time-points (24 h and six months) tested. After 24 h storage, all specimens were subjected to the bottom/top hardness ratio analysis. Then, the push-out bond strength test was performed in half of the specimens and the other half were maintained for six months on water storage before testing. The failure modes were analyzed in a stereomicroscopic. The data were analyzed statistically using one- and two-way ANOVA and Tukey post-test (p <0.05). Results: There were no statistically significant differences for the bottom/top hardness ratio among the resin composites (p>0.05). Regardless of the storage timepoint, regular bulk-fill resin composites showed the highest bond strength values statistically (p<0.05). Only conventional resin composites showed statistically lower bond strength values at six-month storage (p<0.05). Adhesive failures were more predominant for low-viscosity bulk-fill resin composites. Conclusion: Although the DoC was not affected by different materials tested, only bulk-fill resin composites did not present dentin bond strength loss after six-month of water storage


Subject(s)
Dental Bonding , Composite Resins , Dental Materials , Longevity
5.
Braz. oral res. (Online) ; 37: e047, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1439732

ABSTRACT

Abstract To evaluate the feasibility of using a milled polyetheretherketone (PEEK) post and core in endodontically treated teeth with or without a ferrule. Sixty bovine tooth roots were endodontically treated followed by cementation of intraradicular retainers (IR), according to each experimental group: a) non-ferrule glass fiber post (f0FP); b) 2-mm-ferrule glass fiber post (f2FP); c) non-ferrule resized glass fiber post (f0PR); d) 2-mm-ferrule resized glass fiber post (f2PR); e) non-ferrule PEEK post and core (f0PPC); and f) 2-mm-ferrule PEEK post and core (f2PPC). Metal crowns were made and cemented. A periodontal ligament was simulated using polyether. A force was applied to the palatine portion of each sample at 45°, until fracture. Fracture resistance data were submitted to two-way ANOVA and Tukey's test (α = 0.05). Three-dimensional digital models were developed to calculate the tensions formed in the root using finite element analysis. Models of glass fiber posts and PEEK posts and cores were evaluated with or without a ferrule. The results were analyzed by the Mohr-Coulomb criterion. The type of IR was not influenced by fracture strength (p = 0.243). There were significant statistical differences among the remaining factors. Ferrule groups had greater fracture resistance, and the failure mode of teeth with a ferrule was more catastrophic than the non-ferrule group. A ferrule increases fracture resistance and influences failure mode; the PEEK post and core did not modify the biomechanics of endodontically treated teeth, and resembled the glass fiber post results. The crack initiation point differed between the ferrule and non-ferrule groups.

6.
Braz. oral res. (Online) ; 37: e42, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1430032

ABSTRACT

Abstract The purpose of this study was to evaluate the effect of dentin moisture (moist and dry) on the bonding of fiber posts to root dentin with different adhesive strategies (etch-and-rinse, self-etch, and self-adhesive). Seventy-two extracted single-rooted human teeth were endodontically treated and divided into six groups (n = 12) according to the moisture of dentin surface and adhesive systems as follows: a) etch-and-rinse/moist, b) etch-and-rinse/dry, c) self-etch/moist, d) self-etch/dry, e) self-adhesive/moist, and 6) self-adhesive/dry. The specimens were sectioned into six slices for push-out bond strength (BS), nanoleakage (NL) by SEM, and Vickers microhardness (VHN) of the resin cement. A universal testing machine (AG-I, Shimadzu Autograph) was used at a crosshead speed of 0.5 mm/min until post extrusion, with a load cell of 50 kg for evaluation of the push-out strength. Data on BS, NL, and VHN were evaluated by two-way ANOVA and Tukey's test (α = 0.05). Dentin moisture as the main factor was not significantly different for the push-out test. However, higher BS values can be observed for the etch-and-rinse group. A lower percentage of NL was found in the dry dentin groups. The moisture pattern was not significant in the hardness values for the pre-etching groups. Additional moisture did not increase the evaluated properties.

7.
Pesqui. bras. odontopediatria clín. integr ; 23: e210190, 2023. tab, graf
Article in English | LILACS, BBO | ID: biblio-1521294

ABSTRACT

ABSTRACT Objective: To find out what the acid-base resistant zone (ABRZ) is and the mechanism of its formation. Material and Methods: This systematic review was based on the search of laboratory studies in which selfetching adhesive systems were used. The electronic database PubMed was used for the search. The search began on August 2021 and ended on June 2022. We have analyzed the materials and methods of each research and entered them in the appropriate tables to give a clearer assessment of the obtained results. Results: This systematic review included 15 full-text articles published from 2011 to 2019. The ABRZ is formed on both dentine and enamel. On dentine, the ABRZ is formed only when using self-etching adhesive systems; on the enamel, on the contrary, the step of preliminary etch and rinse contributes to the formation of a thicker ABRZ. The functional monomer MDP and fluorine increase the thickness of the ABRZ and provide a hybrid layer /ABRZ boundary without defects and erosions. Conclusion: Self-etching adhesive systems ensure the creation of an ABRZ resistant to acid-base tests. This phenomenon can provide the resistance of tooth tissues to demineralization, and therefore increase their resistance to caries.


Subject(s)
Acid Etching, Dental , Dental Bonding/methods , Dentin-Bonding Agents/chemistry
8.
Braz. j. oral sci ; 22: e239389, Jan.-Dec. 2023. ilus
Article in English | LILACS, BBO | ID: biblio-1509457

ABSTRACT

Aim: The purpose of this study was to investigate the biofilm effect on the hybrid ceramic-resin cement bond strength (BS) by comparing two methods. Methods: Teeth were distributed into groups (n=5), according to the resin cement (Maxcem Elite-(MC) or NX3 Nexus-(NX)) and degradation method (24h or 7 days in distilled water; 7 or 30 days incubated with biofilm and 30 days in sterile media). Treated surfaces of Vita Enamic blocks (5x6x7mm) were luted to treated or no treated dentin surfaces and light-cured. After 24h, beams were obtained (1x1x10mm) and stored accordingly. The flexural bond strength (FBS) was assessed by four-point bending test. Additional beams were obtained from new teeth (n=5), stored for 24h or 7 days in distilled water, and submitted to a microtensile bond strength (µTBS) assay. Failure modes were determined by scanning electron microscopy (100X). The flexure strength of the cements (n=10) was assessed by a four-point bending test. Data were analyzed by 1 and 2-ways ANOVA, and Tukey's test (α=0.05). Results: There was no significant difference between the degradation methods for the FBS groups. For the µTBS, the significant difference was as follows: NX 7days > NX 24h > MC 7days = MC 24h. Failure mode was mainly adhesive and mixed, but with an increase of cohesive within cement and pre-failures for the MC groups assessed by µTBS. NX had better performance than MC, regardless of the method. Conclusions: The biofilm had no effect on the materials BS and FBS test was a useful method to evaluate BS of materials with poor performance


Subject(s)
Tensile Strength , Microscopy, Electron, Scanning , Dental Bonding , Biofilms , Resin Cements
9.
Medicentro (Villa Clara) ; 26(4): 897-914, oct.-dic. 2022. tab
Article in Spanish | LILACS | ID: biblio-1405681

ABSTRACT

RESUMEN Introducción: Buscando satisfacer la demanda con procedimientos adhesivos más rápidos, menos sensibles a la técnica y facilidad de uso, se han desarrollado los adhesivos universales, que brindan al profesional la opción de seleccionar la estrategia de adhesión con diferentes modos de grabado, ya sea con grabado y enjuague, autograbado o grabado selectivo. Debido a la poca información existente, se han generado dudas sobre el rendimiento, propiedades y la aplicación de una técnica adhesiva adecuada sobre los tejidos dentales. Objetivo: Determinar el nivel de adhesión con el uso de adhesivos universales en modo de grabado y enjuague y autograbado. Métodos: Se realizó una revisión de la literatura, a través de la búsqueda electrónica en las bases de datos: SciELO, Scopus, PubMed, Springer y EBSCO. Inicialmente se seleccionaron por título y resumen, artículos duplicados se consideraron solo una vez, se incluyeron artículos de acceso libre y pagos, escritos en idioma español e inglés, publicados desde el año 2015, de los cuales 39 artículos fueron seleccionados para el estudio. Conclusiones: El uso de adhesivos universales sobre dentina presenta un nivel de adhesión mayor cuando se aplica en modo de autograbado. La aplicación activa del adhesivo universal en esmalte mejora la fuerza y resistencia de unión. El nivel de adhesión en el esmalte es mayor cuando se aplica en modo de grabado y enjuague. La resistencia inicial y por fatiga del adhesivo, no mejora con los tiempos prolongados del grabado ácido.


ABSTRACT Introduction: universal adhesives have been developed to satisfy the demand with faster adhesive procedures, less sensitive to the technique and ease of use, which offer the professional the option of selecting the adhesion strategy with different etching modes, either with etch-and-rinse, self-etch or selective etching ones. Doubts have been generated about the performance, properties and application of an adequate adhesive technique on dental tissues due to the little existing information. Objective: to determine the level of adhesion with the use of universal adhesives in etch-and-rinse and self-etch modes Methods: an electronic search of the literature was carried out in SciELO, Scopus, PubMed, Springer and EBSCO databases. Initially, articles were selected by title and abstract, duplicate ones were considered only once, free and paid access articles, written in Spanish and English and published since 2015 were included; 39 of them were selected for the study. Conclusions: the use of universal adhesives on dentin presents a higher level of adhesion when applied in self-etch mode. The active application of the universal adhesive improves the enamel bond strength. The level of adhesion on the enamel is higher when applied in etch-and-rinse. The initial fatigue resistance of the adhesive does not improve with prolonged acid etching times.


Subject(s)
Acid Etching, Dental , Dental Bonding , Dentin-Bonding Agents
10.
Acta odontol. latinoam ; 35(3): 155-163, Dec. 2022. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1419941

ABSTRACT

ABSTRACT The objective of this study was to evaluate the microtensile bond strength (μTBS) to dentin of two universal adhesive systems: Single Bond Universal (SBU) and Ambar Universal , used in different adhesion strategies. Materials and Method: Thirty-six human teeth were prepared (n=6) and treated following different adhesive strategies: G1: SBU-etch-and-rinse, applied on dry dentin; G2: SBUetch- and-rinse, applied on moist dentin; G3: SBU-self-etching; G4: AU-etch-and-rinse, applied on dry dentin; G5: AU-etch-and-rinse, applied on moist dentin; G6: AU-self-etching. The specimens were submitted to μTBS test, failure analysis, and scanning electron microscopy (SEM). Data were analyzed with ANOVA and Tukey's tests (p<0.05). Results: Microtensile bond strength was significantly lower in G1 than G2 and G3. AU adhesive performed worse than the SBU system, except in G5. Cohesive and mixed failures predominated in G1 and G2, while adhesive failures predominated in G3 and G5. Conclusions: Universal adhesives are an interesting innovation, but there are still doubts about their performance, mainly regarding the different protocols provided by the manufacturers. The conventional adhesive strategy on moist dentin demonstrated higher μTBS for both adhesives. The use of the selfetching strategy with the SBU showed promising results.


RESUMO O objetivo deste estudo foi avaliar a resistência de união à microtração (μTBS) de dois sistemas adesivos universais: Single Bond Universal (SBU) e Ambar Universal , utilizados em diferentes estratégias de adesão. Materiais e método: 36 dentes humanos foram preparados (n=6) e tratados seguindo diferentes estratégias adesivas: G1: SBU-condicionamento e enxágue, aplicado sobre dentina seca; G2: SBU-condicionamento e enxágue, aplicado sobre dentina úmida; G3: SBU-autocondicionante; G4: AU-condicionamento e enxágue, aplicado em dentina seca; G5: AU-condicionamento e enxágue, aplicado sobre dentina úmida; G6: AU-autocondicionante. Os espécimes foram submetidos ao teste de μTBS, análise de falhas e microscopia eletrônica de varredura (SEM). Os dados foram analisados com os testes ANOVA e Tukey (p<0,05). Resultados: A resistência de união à microtração de G1 foi significativamente menor que G2 e G3. O adesivo AU teve um desempenho pior que o sistema SBU, com exceção do G5. Falhas coesivas e mistas predominaram em G1 e G2 enquanto G3 e G5 apresentaram predominância de falhas adesivas. Conclusões: Os adesivos universais representam uma inovação interessante, mas ainda há dúvidas sobre seu desempenho, principalmente em relação aos diferentes protocolos fornecidos pelos fabricantes. A estratégia adesiva convencional em dentina úmida demonstrou maior μTBS para ambos os adesivos. O uso da estratégia autocondicionante com a SBU apresentou resultados promissores.

11.
Rev. ADM ; 79(1): 20-27, ene.-feb. 2022. ilus, tab
Article in Spanish | LILACS | ID: biblio-1361506

ABSTRACT

Los sistemas cementantes han mejorado notablemente, los objetivos que persiguen los nuevos cementos es que la adhesión sea duradera y conseguir siempre que sea posible una interface cerrada con un sellado perfecto. Se han podido desarrollar nuevas técnicas y nuevos materiales de cementación que han ido perfeccionando la unión del material restaurador al diente. En el presente estudio se compara la fuerza de adhesión a dentina de cementos de autograbado y cementos de grabado total para comprobar los efectos positivos en el grabado de la dentina. Para el estudio se utilizaron dos cementos a base de resina (RelyX U200 Clicker 3M y RelyX Ultimate 3M). Se encapsularon 40 molares en acrílico en dos grupos de 20 muestras para la aplicación de dos sistemas cementantes de autograbado (grupo 1) y de grabado total (grupo 2), respectivamente, se desgastaron hasta descubrir la dentina; siguiendo las especificaciones del fabricante se colocó el cemento en cada grupo, y después se sometieron a pruebas de cizalla en una máquina de ensayo universal Instron. La medida expresada en megapascales (MPa) fue: grupo 1 = 7.5569 y grupo 2 = 12.6444. En este caso fueron analizados dos grupos, tomándose la primera significancia bilateral. Se realiza la prueba en t de Student, con 95% de intervalo de confianza en la diferencia, demostrando así que el cemento RelyX Ultimate 3M tiene mayor fuerza de adhesión que el cemento RelyX U200 Clicker 3M. Nuestra investigación fue factible y llegamos a nuestro propósito, en el cual comprobamos la mayor adhesión de cementos de grabado total, los cuales son sometidos a un previo tratamiento del diente (AU)


Subject(s)
Humans , Adolescent , Adult , Acid Etching, Dental , Cementation , Dentin-Bonding Agents , Resin Cements , Shear Strength , Tensile Strength , Dentin/drug effects
12.
Braz. dent. sci ; 25(3): 1-8, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1373117

ABSTRACT

Objective: To evaluate the ability of different separating mediums to prevent adhesion between provisional restorations and hybridized dentin surfaces when used with the Immediate Dentin Sealing technique (IDS). Material and Methods: 120 extracted human teeth ­ 40 premolars and 80 molars ­ were selected to integrate acrylics samples separated into 4 different groups (n=10) according to the separating medium used for IDS protection. Forty samples were made of three teeth mounted in a self-cure acrylic resin block (Jet, Classic, São Paulo, Brazil) arranged side by side, simulating the positioning and proximal contacts present in the dental arch between the second premolar, first molar and second molar. A standard dental preparation for ultra-thin occlusal veneer was performed and complete occlusal dentin exposure was achieved by selective removal of the occlusal enamel with a high-speed conical round burr (Code: 1801.4138 FG, KG Sorensen, Medical Burs Ind. e Com. de Pontas e Brocas Cirúrgicas Ltda, São Paulo, Brazil). Dentin hybridization were performed on the control group and 3 different groups of separating mediums (n=10): PC­commercial provisional separating agent (Pro-V Coat, Bisco, Schaumburg, USA); GG­glycerin gel (K-Y Gel; Johnson & Johnson Industry and Commerce LTDA, São Paulo, Brazil); PJ­petroleum jelly (Rioquímica, São Paulo, Brazil). Provisionalization were manufactured on the prepared teeth. After 2 weeks, the tensile test was performed, and the analysis of the failure pattern was performed by 3D laser confocal microscopy and Scanning Electron Microscopy (SEM). The data were analyzed with the 1-way ANOVA and the Tukey test (α = 0.05). Results: Significantly lower tensile strength values were found for the commercial provisional separating agent (30.39 ± 10.01 N) compared to others (p < 0.05). Conclusion: The commercial provisional separating agent showed greater effectiveness on protecting hybridized dentin against the provisional restorations (AU)


Objetivo: Avaliar a capacidade de diferentes agentes isolantes em prevenir a adesão entre as restaurações provisórias e a superfícies de dentina hibridizadas quando usados com a técnica do Selamento Dentinário Imediato (IDS). Material e Métodos: 120 dentes humanos extraídos - 40 pré-molares e 80 molares - foram selecionados para integrar as amostras de acrílico divididas em 4 grupos diferentes (n = 10) de acordo com o meio de separação usado para proteção IDS. Foram confeccionadas 40 amostras de três dentes montados em um bloco de resina acrílica autopolimerizável (Jet, Classic, São Paulo, Brasil) dispostos lado a lado, simulando o posicionamento e os contatos proximais presentes na arcada dentária entre o segundo pré-molar, primeiro molar e segundo molar. Um preparo dentário padrão para laminado oclusal ultrafino foi realizado e a exposição completa da dentina oclusal foi obtida pela remoção seletiva do esmalte oclusal com uma broca cônica arredondada de alta rotação (Código: 1801.4138 FG, KG Sorensen, Medical Burs Ind. E Com. de Pontas e Brocas Cirúrgicas Ltda, São Paulo, Brasil). A hibridização da dentina foi realizada no grupo controle e em 3 grupos diferentes de agentes isolantes (n = 10): PC - agente de separação provisório comercial (Pro-V Coat, Bisco, Schaumburg, EUA); GG ­ gel de glicerina (K-Y Gel; Johnson & Johnson Industry and Commerce LTDA, São Paulo, Brasil); PJ ­ vaselina (Rioquímica, São Paulo, Brasil). As restaurações provisórias foram fabricadas nos dentes preparados. Após 2 semanas, foi realizado o teste de tração, e a análise do padrão de falha foi realizada por microscopia confocal a laser 3D e Microscopia Eletrônica de Varredura (MEV). Os dados foram analisados com a ANOVA de 1 fator e o teste de Tukey (α = 0,05). Resultados: Valores de resistência à tração significativamente menores foram encontrados para o agente separador provisório comercial (30,39 ± 10,01 N) em comparação com os demais (p < 0,05). Conclusão: O agente separador provisório comercial mostrou maior eficácia para a proteção da dentina hibridizada contra as restaurações provisórias (AU)


Subject(s)
Humans , Dentin-Bonding Agents , Dental Restoration, Temporary , Dentin
13.
Braz. dent. sci ; 25(1): 1-9, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1361885

ABSTRACT

Objetivo: O objetivo foi avaliar a resistência de união de seis adesivos experimentais contendo sistemas fotoiniciadores binários ou ternários, associados a três diferentes concentrações de MDP (0-12% em peso) após 12 meses de armazenamento em água destilada. Material e Métodos: Adesivos experimentais foram preparados com: bis-GMA, UDMA, bis-EMA, TEGDMA, HEMA, BHT e etanol, contendo sistemas fotoiniciadores binários (CQ/amina) ou ternários (CQ/amina/DPIHFP ­ 0,5% em peso). Foi adicionado a esta composição 0%, 6% ou 12% em peso de MDP. Os sistemas adesivos foram aplicados seguindo o protocolo com condicionamento ácido. Moldes cilíndricos transparentes foram colocados sobre a dentina hibridizada, preenchidos com resina composta e fotopolimerizados. Os corpos-de-prova foram armazenados em água destilada a 37oC por 24h ou 12 meses e submetidos ao ensaio de microcisalhamento (n=6). Os dados foram analisados por ANOVA de três fatores e teste de Tukey (α=5%). Resultados: Para o sistema binário, após 12 meses de armazenamento, todos os valores de resistência de união foram semelhantes. Em relação à degradação da resistência de adesão ao longo do tempo, as formulações de MDP de 6% e 12% mostraram resistência de união mais estável do que 0% de MDP. Para o sistema ternário, todas as formulações (0%, 6% e 12% em massa de MDP) mostraram resistência de união estável em função do tempo. Conclusão: Para o sistema binário, as concentrações de 6 e 12% em massa de MDP foram capazes de manter a resistência de união em função do tempo, enquanto que para o sistema ternário, a estabilidade de união foi obtida independentemente da concentração de MDP. Pode-se concluir que, para a formulação dos adesivos utilizados neste estudo, independente do sistema fotoiniciador, a concentração de 12% MDP apresentou valores de resistência de união mais estáveis após 12 meses de armazenamento em água (AU)


Objective: The aim was to evaluate the bond strength of six experimental adhesives containing binary or ternary photoinitiator systems, associated with three different MDP concentrations (0-12wt%) after 12 months of storage in distilled water. Material and Methods: Experimental adhesives were prepared with: bis-GMA, UDMA, bis-EMA, TEGDMA, HEMA, BHT, and ethanol, containing binary (CQ/amine) or ternary (CQ/amine/DPIHFP (diphenyliodonium hexafluorophosphate) ­ 0.5wt%) photoinitiator systems. It was added to this composition 0wt%, 6wt%, or 12wt% of MDP. The adhesive systems were applied following the etch-and-rinse protocol. Transparent cylindrical molds were placed on the hybridized dentin, filled with composite resin and light-cured. The specimens were stored in distilled water at 37oC for 24h or 12 months and submitted to a microshear bond strength test (n=6). Data were analyzed by three-way ANOVA and Tukey's test (α=5%). Results: For the binary system, after 12 months of storage, all bond strength values were similar. Regarding bond strength degradation over time, 6wt% and 12wt% MDP formulations showed more stable bond strength than 0wt% MDP. For the ternary system, all formulations (0wt%, 6wt% and 12wt%) showed stable bond strength over time. Conclusion: For the binary photoinitiator system, the 6wt% and 12wt% MDP concentrations were able to keep bond strength stable over time, while for the ternary system, bond strength stability was achieved regardless the MDP concentration. (AU)


Subject(s)
Dental Cements , Photoinitiators, Dental
14.
Pesqui. bras. odontopediatria clín. integr ; 22: e210193, 2022. tab, graf
Article in English | LILACS, BBO | ID: biblio-1422269

ABSTRACT

Abstract Objective: To evaluate and compare the shear bond strengths (SBS) and bracket failure rates (BFR) of orthodontic brackets bonded with Light Cure adhesive against those bonded with Self Cure adhesive. Material and Methods: The study had in vitro and in vivo parts. In the in vitro part to determine SBS of Light Bond(LB)(R) and Rely.a.Bond(RB)(R) adhesives used in bonding brackets to 88 extracted teeth, each adhesive type was used to bond 44 brackets. The clinical study was conducted to determine the BFR of the LB(R) and RB(R) adhesives by bonding 256 teeth using each adhesive type. A standardized bonding procedure was followed in both the in vitro and in vivo parts of the study. Data were analyzed using frequency, percentage, mean, independent t-test, chi-square, and Pearson Correlation statistics. A p-value of ≤ 0.05 was considered significant. SPSS version 21.0 was used to analyze the data generated. Results: There was a significantly higher mean SBS 10.6MPa for LB(R) adhesive than the 7.0MPa of the RB(R) adhesive. In the in vivo study, (LB)(R) had a greater but not significant BFR of 9.0% than RB(R) (8.0%). No significant relationship existed between the SBS of either adhesive type (as determined in vitro) and their BFR in vivo. Conclusion: Higher SBS of LB(R) did not translate to less BFR in the clinic, nor did a lower SBS of RB(R) translate to more BFR in the clinic (AU).


Subject(s)
Humans , Dental Bonding/instrumentation , Orthodontic Brackets , Dentin-Bonding Agents , Shear Strength , In Vitro Techniques/methods , Chi-Square Distribution
15.
Article in English | LILACS, BBO | ID: biblio-1422278

ABSTRACT

Abstract Objective: To evaluate the microleakage at the junction between amalgam-composite resin restorations using different bonding systems. Material and Methods: In this in-vitro study, standard class II cavities were prepared on 40 human maxillary premolars. The axial and gingival floor depths of the cavities were 2 mm and 1 mm below (cementoenamel junction), respectively. The samples were divided into 4 groups (n = 10). In all groups, a layer of 1-mm thick amalgam was used as a coating for the initial part of the gingival floor. In group 1, no bonding system was used for amalgam restoration. In group 2, G-Premio Bond was applied. G-Premio bond + alloy primer and single bond + alloy primer were used in group 3 and group 4, respectively. The rest of the cavities in all groups were then repaired using FiltekZ250 composite. The samples were thermocycled at 500 rpm and immersed in 1% methylene blue solution for 24 hours to allow dye penetration. Once cut, the samples were placed under a stereomicroscope (40X) to determine the microleakage rate. Data analysis was carried out using post-hoc and Chi-square tests (p<0.05). Results: The highest and lowest microleakage rate was related to groups 1 and 3, respectively. There was a significant difference between groups (1,2) and (1,3), and (1,4), and groups (2,3) (p<0.05). Conclusion: The use of alloy primer and bonding could reduce the microleakage between the two restorations (AU).


Subject(s)
Humans , Dentin-Bonding Agents , Composite Resins , Dental Leakage , Dental Restoration, Permanent , In Vitro Techniques/methods , Chi-Square Distribution , Dental Bonding
16.
Braz. oral res. (Online) ; 36: e093, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1384196

ABSTRACT

Abstract: The aim of the study was to evaluate how the association of solvents (tetrahydrofuran [THF], dimethyl sulfoxide [DMSO], ethanol [ET] or acetone [ACT]) with experimental dental adhesives affects selected properties of experimental dental adhesives and dentin bond durability. Six adhesive combinations were prepared containing: 30 % ET, 30 % ACT, 30 % THF, 28 % ET + 2 % DMSO (ET+DMSO), 15 % ethanol + 15 % THF (ET+THF), or 28 % THF + 2 % DMSO (THF+DMSO). Thirty-six molars (n = 6) were cut to expose the coronary dentin, and were randomly divided according to the adhesives. They were restored, and then cut into resindentin sticks (1 mm²), and stored in distilled water for 24 h or 6 months, until conducting the microtensile bond strength and nanoleakage tests. Other experiments performed with adhesives included viscosity assessment using a rheometer, and degree of conversion using Fourier-transform infrared spectroscopy (FTIR). The data were analyzed statistically using two-way ANOVA and Tukey's test (p < 0.05). The adhesive formulated exclusively with THF showed the highest viscosity, followed by ET+THF, which obtained the highest degree of conversion compared to ET, and THF alone. ET+DMSO obtained the highest 24-h and aged bond strengths (p < 0.05). ET+THF increased the nanoleakage slightly after 6 months, but attained the only gap-free adhesive interface among all the groups. The combination of alternative solvents, particularly THF, with conventional ones (ET) has improved chemical properties, and the dentin bonding of experimental simplified adhesives.

17.
Arq. odontol ; 58: 131-139, 2022. tab, graf
Article in English | LILACS, BBO | ID: biblio-1411880

ABSTRACT

Aim: To compare the influence of prophylaxis with sodium bicarbonate and amino acid glycine powder on the bond strength of bovine teeth enamel and on the properties of two adhesive systems. Methods:Thirty-six extracted bovine incisors were randomly divided into six groups (n = 6) according to the prophylactic treatment received: no prophylactic treatment (NT), sodium bicarbonate powder (SB), and glycine powder (GL). Each group was subdivided into 2 groups based on what adhesive systems were used: conventional system (A) and universal system (B). Composite resin was applied on the buccal surface of the teeth in a block measurement 8x8x6 mm. The specimens were cut to obtain beams measuring 1.0 x 1.0 mm and were subjected to microtensile bond strength tests. Results were compared using two-way ANOVA (p ≤ 0.05). Results: The GLA group obtained the highest bond strength value for the conventional adhesive (18.97 MPa), but the GLB group obtained a lower strength value than the SBB group (GLB: 21.05 MPa and SBB: 22.29 MPa) (p < 0.05). Conclusions: Cleaning of the enamel surface increases the adhesive properties of restorative materials, and the bond strength was more effective in the group that received glycine prophylaxis and the conventional adhesive system.


Objetivo:Comparar a influência da profilaxia com bicarbonato de sódio e ClinproProphy ™ na resistência de união do esmalte de dentes bovinos e nas propriedades de dois sistemas adesivos.Métodos: Trinta e seis incisivos bovinos extraídos foram divididos aleatoriamente em 6 grupos (n = 6), cada um de acordo com o tratamento profilático recebido: nenhum tratamento profilático (NT), bicarbonato de sódio em pó (SB), glicina em pó (GL). Cada grupo foi subdividido em 2 grupos com base nos sistemas adesivos utilizados: sistema convencional (A) e sistema universal (B). A resina composta foi aplicada na superfície bucal dos dentes em um bloco de 8x8x6 mm. As amostras foram cortadas para obter blocos medindo 1,0 x 1,0 mm e submetidas a testes de resistência de união por microtração. Os resultados foram comparados usando o teste two-way ANOVA (p ≤ 0,05). Resultados: O grupo GLA obteve o maior valor de resistência de união para o adesivo convencional (18,97 MPa), mas o grupo GLB obteve um valor de resistência menor que o grupo SBB (GLB: 21,05 MPa e SBB: 22,29 MPa) (p < 0,05). Conclusão: A limpeza da superfície do esmalte aumenta as propriedades adesivas dos materiais restauradores, e a resistência adesiva foi mais eficaz no grupo que recebeu profilaxia com glicina e sistema adesivo convencional.


Subject(s)
Tensile Strength , Dental Bonding , Dental Enamel , Dental Prophylaxis , Glycine
18.
Odovtos (En línea) ; 23(3)dic. 2021.
Article in English | LILACS, SaludCR | ID: biblio-1386545

ABSTRACT

ABSTRACT: Evaluate the effect on the shear bond strength (SBS) of 5% NaOCl applied after acid etching on ground anterior teeth with fluorosis and analyze the surface with scanning electron microscopy (SEM), also compare fluorotic and healthy ground enamel by atomic force microscopy (AFM) and Vickers microhardness (VM). For the SBS test 30 anterior teeth with moderate and severe fluorosis according Dean index were selected by an examiner previously calibrated with an expert in fluorosis by using the intraclass correlation coefficient (ICC). With the help of a calibrated high speed diamond bur for veneer preparation and a parallel chamfer high speed diamond bur he vestibular face was prepared with a uniform reduction of .3 mm under water cooling. In one half of the vestibular face of the teeth the conventional adhesive procedure was carried out while in the other half was added an additional step with 5% NaOCl applied for 1 minute and washing after acid etchant. A resin post was adhered in each half and load was applied until fracture. The failure mode was evaluated and a SEM analysis was made. Posteriorly 10 samples of fluorotic and healthy ground enamel were used to measure the nanostructural characteristics by AFM (roughness average and absolute depth profile) and the VM in three operative steps (after ground, after etchant and after deproteinization). The Shapiro-Wilks and Brown-Forsythe methods were used to test the distribution of variables. The Paired Student's t-test was used to compare the differences between mean bond strength (MPa) in the two groups for SBS test. Chi- square analyzes were performed to compare the failure modes between groups. One- way ANOVA analysis and Tukey-Kramer post hoc test were used to compare groups for roughness average, absolute depth profile and Vickers microhardness. A greater SBS (32.17±4.20 MPa) and a surface more homogeneous and less contaminated were observed in the deproteinization subgruoup compared to the conventional subgroup (27.74±4.88 MPa). AFM parameters were greater in fluorosis subgroup than in healthy enamel subgroup. VM was lower in the fluorotic enamel in each operative step in comparation with healthy enamel. The use of 5% NaOCl as a deproteinizing agent after acid etchant in ground fluorotic enamel results in better adhesion, which may imply greater success in adhesive treatments. The ground surface of fluorotic enamel shows higher values of roughness and depth and lower values of VM which proves that there is a more irregular and less hard surface.


RESUMEN: Evaluar el efecto en la resistencia adhesiva al cizallamiento (SBS) de la aplicación de 5% de NAOCl después del grabado ácido en dientes anteriores fluoróticos tallados y analizar la superficie con microscopía electrónica de barrido (SEM), también comparar esmalte tallado fluorótico y sano por microscopía de fuerza atómica (AFM) y microdureza Vickers (VM). Para la prueba SBS 30 dientes anteriores con fluorosis moderada y severa de acuerdo al índice de Dean fueron seleccionados por un examinador previamente calibrado por un experto en fluorosis usando el coeficiente de correlación intraclase (ICC). La cara vestibular se preparó .3mm con la ayuda de una fresa calibrada para la preparación de carillas y una paralela con punta en chamfer de diamante a alta velocidad e irrigación. En una mitad de la superficie vestibular de los dientes se llevó a cabo el procedimiento adhesivo tradicional, mientras que en la otra mitad se incluyó un paso adicional con la aplicación de NaOCl al 5% por un minute y lavado posterior al grabado ácido. Un poste de resina fué adherido en cada mitad y se aplicó carga hasta la fractura. Se evaluó el modo de fallo y se realizó un análisis con SEM. Posteriormente se utilizaron 10 muestras de esmalte tallado fluorótico y sano para medir las características nano estructurales por medio de AFM (rugosisdad promedio y perfil de profundidad absoluta) y la VM en tres diferentes pasos operativos (posterior al tallado, posterior al grabado ácido y posterior a la desproteinización). Se utilizaron los métodos de Shapiro Wilks y Brown-Forsythe para conocer la distribución de las variables. Una T de student pareada se utilizó para comparar la diferencia entre los promedios de la fuerza de unión (MPa) entre grupos para la prueba SBS. Se llevaron a cabo análisis de chi cuadrada para comparer los modos de fallo entre los grupos. Análisis de ANOVA de una vía y Tukey-Kramer post hoc fueron utilizados para comparar los grupos para las variables rugosidad promedio, perfil de profundidad absoluta y microdureza Vickers. Se observó una mayor SBS (32,17±4,20 MPa) y una superficie más homogénea y menos contaminada en el subgrupo con desproteinización en comparación con el subgrupo convencional (27,74±4,88 MPa). Los parámetros de AFM fueron mayores en el subgrupo de fluorosis que en el subgrupo de esmalte sano. La VM fue más baja en el esmalte fluorótico en cada paso operativo en comparación con el esmalte sano. El uso de NaOCl al 5% como agente desproteinizante después del grabado ácido en el esmalte fluorótico tallado da como resultado una mejor adhesión, lo que puede implicar un mayor éxito en los tratamientos adhesivos. La superficie tallada del esmalte fluorótico muestra valores más altos de rugosidad y profundidad y valores más bajos de VM lo que prueba que existe una superficie más irregular y menos dura.


Subject(s)
Humans , Sodium Hypochlorite , Dental Bonding , Dental Enamel , Fluorosis, Dental
19.
Braz. j. oral sci ; 20: e210445, jan.-dez. 2021. ilus
Article in English | BBO, LILACS | ID: biblio-1253016

ABSTRACT

Aim. To evaluate the bond durability of two universal adhesives; mild and ultra-mild in both etch-and-rinse and self-etch modes after simulated in-vitro degradation by long-term water storage or thermocycling. Methods. A total of 144 specimens were used in this study; 120 specimens (prepared from 30 teeth) for microshear bond strength testing and fracture mode assessment, and 24 specimens for scanning electron microscopic evaluation (prepared from 24 teeth). Specimens were prepared from 54 recently extracted caries free third molars and randomly divided into 12 groups, according to the adhesive treatment (All Bond or Scotchbond Universal), etching mode (etch-andrinse or self-etch) and aging method (thermocycling or water storage). Each tooth was sectioned mesio-distally into two halves exposing free dentin surface for bonding where dentin substrate 1 mm below the dentino-enamel junction was used. After adhesive application and composite build up, specimens were tested in shear mode after storing in distilled water at 37˚C for 24 hours or 1 year, or after being thermocycled between 5 and 55 °C for 10,000 cycles (n=10). Microshear bond strength (µSBS) was tested using a universal testing machine. Adhesive-dentin interface was examined using scanning electron microscope (SEM) (n=2). Data were analyzed using 3 way AN0VA and pairwise comparisons was performed using Bonferroni correction at significance level of α ≤0.05. Results. Statistical analysis revealed non-significant difference for etching mode in both adhesives (p=0.596). After aging, the bond strength was only reduced in Scotchbond Universal after one year of water storage in both modes (p<0.001). SEM evaluation revealed intact hybrid layer and longer resin tags for etch-and-rinse mode than selfetch mode of both adhesives. Conclusion. The bond strength of universal adhesives is not affected by the etching mode, however its durability was shown to be material dependent


Subject(s)
Dental Bonding , Dental Cements , Dentin
20.
Braz. j. oral sci ; 20: e213641, jan.-dez. 2021. ilus
Article in English | BBO, LILACS | ID: biblio-1254539

ABSTRACT

Aim: To review the current literature regarding the bond strength of self-adhesive flowable resin composites (SAFRCs) to tooth structure, comparing the outcomes with conventional flowable resin composites (CFRCs). Methods: PubMed/Medline, EbscoHost and Scopus databases were screened (last update on November 2020) using related Medical Subject Headings (MeSH) and free terms. We included in vitro studies published in English language comparing the bond strength of SAFRCs and CFRCs to enamel and/or dentin from primary and/or permanent teeth. Results: In total, 23 articles were included. Unlike CFRCs, SAFRCs such as Vertise® Flow and Fusio™ Liquid Dentin exhibited statistically lower bond strength to enamel and dentin from permanent teeth. There were limited studies comparing the enamel bond strength of CFRCs and SAFRCs (prior phosphoric acid etching and/or adhesive system use). Also, we found few studies that evaluated the bonding effectiveness of Constic® and other SAFRCs to primary teeth. Conclusions: Current SAFRCs showed low bond strength to permanent teeth, which impedes to recommend them as a reliable alternative to CFRCs. The bonding performance of Constic® on both hard dental tissues should be evaluated on future studies. Also, more evidence assessing the bond strength of SAFRCs to primary teeth and etched enamel is needed


Subject(s)
Dental Bonding , Composite Resins , Systematic Reviews as Topic
SELECTION OF CITATIONS
SEARCH DETAIL